Carrier
Ditec
Bosch
Avigilon
Paxton
HKC
Advanced Fire
C-Tec

C-Tec CFP Standard 2 Zone Conventional Fire Alarm Panel

SKU: XN01-CFP702-4 In stock
Key features
  • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13. compliance from the BSI.
  • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
  • Manufactured by C-TEC in the UK.
  • Two detector zone circuits.
  • Four conventional sounder circuits*
  • Max. devices per detector zone 25 detectors (or 32 detectors/manual call points combined).
  • No. of conventional sounder circuits 4 (Max. length per circuit is 500m).
  • Alarm voltage 27V max, 20V min (final battery voltage).
  • Max. sounder output current 4 x 200mA (800mA total).
  • Integral 1.5A EN54-4/A2 compliant switch mode PSU.
  • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
  • Two on-board relays (Fire and Fault).
  • Two open-collector outputs (Remote and Reset).
  • Class change' and alert inputs.
  • Installer-friendly design.
  • Attractive flush or surface mountable plastic lid and enclosure - no bezel required.
  • Low 25mA quiescent current.
  • Multiple indicators.
  • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
  • Space for two x 12V 3.3Ah VRLA batteries.
  • Fully compatible with C-TEC's ActiV range of conventional fire detectors
  • Show all product specifications Show Less
    fast delivery Delivery in 1-2 days (Ireland)
    refund 30 days Exchange or Refund

    Product specifications printPrint

    Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13. compliance from the BSI.
    Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
    Manufactured by C-TEC in the UK.
    Two detector zone circuits.
    Four conventional sounder circuits*
    Max. devices per detector zone 25 detectors (or 32 detectors/manual call points combined).
    No. of conventional sounder circuits 4 (Max. length per circuit is 500m).
    Alarm voltage 27V max, 20V min (final battery voltage).
    Max. sounder output current 4 x 200mA (800mA total).
    Integral 1.5A EN54-4/A2 compliant switch mode PSU.
    Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
    Two on-board relays (Fire and Fault).
    Two open-collector outputs (Remote and Reset).
    Class change' and alert inputs.
    Installer-friendly design.
    Attractive flush or surface mountable plastic lid and enclosure - no bezel required.
    Low 25mA quiescent current.
    Multiple indicators.
    System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
    Space for two x 12V 3.3Ah VRLA batteries.
    Fully compatible with C-TEC's ActiV range of conventional fire detectors

    Specification type

    • Input Voltage 12V DC

    Warranty

    • #Basic warranty##1 Year#

    Have a security problem?

    We are here to help.

    Call us
    Call us +353 1 860 1880
    Whatsapp
    Whatsapp +353 86 791 5930
    Technical Hub
    Technical Hub Access here
    security image